J. 一墙面区幕墙,层高3.0m,立柱一侧分格宽1.2 m,另一侧分格宽1.5m,两块玻璃,A高1.8 m ,B高1.2m,采用梯
(三角)形部分直接作用于立柱,三角形部分直接作用于横梁后再以集中力传给立柱,
直接作用于立柱:
A左梯形(1.8+0.6)/2×0.75=1.9125 m
2,log1.9125=0.2816
μ
z1(3.6)= -{1.0+[0.8×1.0-1.0] ×0.2816}= -0.9437
μ
z1= -0.9437+(-0.2)= -1.1437
W
K=β
gzμ
zμ
z1 W
0=1.73×1.25×1.1437×450= 1144N/m
2
A右梯形(1.8+0.3)/2×0.75=1.26 m
2,log1.26=0.1004
μ
z1(3.6)= -{1.0+[0.8×1.0-1.0] ×0.1004}= -0.9799
μ
z1= -0.9437+(-0.2)= -1.1799
W
K=β
gzμ
zμ
z1 W
0=1.73×1.25×1.1799×450= 1180N/m
2
B左三角形(1.2+0.6)/2=0.36m
2,log=0.2816
μ
z1(1)= -1.0
μ
z1= -1.0+(-0.2)= -1.2
W
K=β
gzμ
zμ
z1 W
0=1.73×1.25×1.2×450= 1200N/m
2
B右三角形(1.2+0.6)/2=0.36m
2,log=0.2816
μ
z1(1)= -1.0
μ
z1= -1.0+(-0.2)= -1.2
W
K=β
gzμ
zμ
z1 W
0=1.73×1.25×1.2×450= 1200N/m
2
三角(梯)形部分直接作用于横梁后再以集中力传给立柱:
左横梁上梯形(1.5+0.3)/2×0.6=0.54m
2,
μ
z1(1)= -1.0
μ
z1= -1.0+(-0.2)= -1.2
W
K=β
gzμ
zμ
z1 W
0=1.73×1.25×1.2×450= 1200N/m
2
左横梁下三角形形(1.5+0.75)/2=0.5625m
2,
μ
z1(1)= -1.0
μ
z1= -1.0+(-0.2)= -1.2
W
K=β
gzμ
zμ
z1 W
0=1.73×1.25×1.2×450= 1200N/m
2
右横梁上三角形形(1.5+0.75)/2=0.5625m
2,
μ
z1(1)= -1.0
μ
z1= -1.0+(-0.2)= -1.2
W
K=β
gzμ
zμ
z1 W
0=1.73×1.25×1.2×450= 1200N/m
2
右横梁下三角形形(1.5+0.75)/2=0.5625m
2,
μ
z1(1)= -1.0
μ
z1= -1.0+(-0.2)= -1.2
W
K=β
gzμ
zμ
z1 W
0=1.73×1.25×1.2×450= 1200N/m
2
用受荷面积计算立柱上的风荷载标准值,在不同部位有不同值,且计算太烦琐,一般人会搞错,立柱的从属面积